List of changes for portingset: 8.2b DevSchoenberg: # 30722 (BDNT22809): Keep selection in Grid highlighted Date: Tue, 9 May 2006 14:36:34 +0200 (CEST) Created on: DevSchoenberg Type: bugfix Problem Description (Customer terms) If, after starting whinh3512m000, the field in the line that needs to be changed is selected, it turns blue in first instance but when you switch to a different window and move back to the session later on, the field is turned white again. However, when something is entered in the field, all other information in the field is wiped away. Test Procedure See problem description. Affected Executables bw.exe Motive source SDIS:TECH-00000-00823 DevSchoenberg: # 30673 (BDNT22746): Size problem when window maximized Date: Thu, 4 May 2006 16:42:36 +0200 (CEST) Created on: DevSchoenberg Type: bugfix Problem Description (Customer terms) User should have option "Remember the user’s settings" (ttams1100s000). Start session "Functions" (ttadv2560m000) with normal (small) window size. Maximize Window. Close session and restart session. Now session is started but no records are shown in the Grid. After pressing F5, records are shown. Workaround Press F5. Test Procedure See problem description. Affected Executables bw.exe Motive source SDIS:TECH-00000-00720 DevSchoenberg: # 30609 (BDNT22668): Register problems Automation in Central Deployment Mode Date: Fri, 28 Apr 2006 16:32:46 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When using Worktop in Central Deployment mode, sometimes when users login a hangup occurs. All what is seen then is a window "waiting for connection". Sometimes when retried a few times the connection can be established. Workaround Make sure local registry is clean. Test Procedure See problem description. Affected Executables bwc.dll Motive source SDIS:TECH-00000-00263 DevSchoenberg: # 30220 (BDNT22234): Date/time selection on focus in BW Date: Tue, 4 Apr 2006 13:51:46 +0200 (CEST) Created on: DevSchoenberg Type: bugfix Problem Description (Customer terms) Usually when a new record is entered in an editable grid, values of previous record appear as default for every field and new value is selected. But in case of date or time fields, the new value is not selected. Test Procedure See problem description Affected Executables bw.exe Motive source TCS:800-151644 setting by BwPrint Date: Thu, 30 Mar 2006 15:19:05 +0200 (CEST) Created on: MaintBaanIVc Type: bugfix Problem Description (Customer terms) When the collate printer setting for a printer is default set off and a report is sent to the windows printer from the Baan application, BwPrint does not get the collate setting from the printer. Default the collate function in BwPrint is enabled (when the chosen printer supports collating). Workaround Set the collate flag manually. Test Procedure 1. First try to setup your local windows printer (select any windows netwrok printer). In the properties of this windows printer, Go to printing preferences, Advanced, and select 2 copies of paper and UNCHECK Collate button, and press ok and apply to save. 2. In Baan try to have the same device added. 3. Go to any print session, press print, then you have ttstpsplopen, here set 2 copies and enable the preview option. Once you continue, you get a preview screen, Now press the print button. Check if the option COLLATE is UNCHECKED. When there is no collate- checkbox in the print dialog look at the properties of the printer. Affected Executables BwPrint.exe Motive source SDIS:TECH-00000-00619 DevSchoenberg: # 30020 (BDNT21905): BW error message window cannot be maximized Date: Fri, 24 Mar 2006 10:03:02 +0100 (CET) Created on: MaintCorelli Type: bugfix Problem Description (Customer terms) The BW Error Message Window can be resized, but the maximize option (icon top right corner of the window and in the pull down menu) is disabled. Workaround N/A Test Procedure Start any environment using BW. Make sure an error will occurr e.g. wrong password. When the error message window appears try to maximize it using the mximize icon on the top right corner of the window. Affected Executables bw.exe Motive source SDIS:TECH-00000-00526 DevSchoenberg: # 29980 (BDNT22016): Introduce TIV number for BW Date: Wed, 22 Mar 2006 16:24:02 +0100 (CET) Created on: DevSchoenberg Type: bugfix Problem Description (Customer terms) Internal Test Procedure Use new macro (defined in bic_bshell) srv.display.tiv(). This macro will return 0 when called for a BW which does not yet support TIV. Else this macro will return the actual BW TIV number. Affected Executables bw.exe bshell.exe DevSchoenberg: # 29680 (BDNT21735): TCS800-151405 CNTRL-M does not start details session Date: Wed, 1 Mar 2006 12:22:23 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When in a session the keyboard focus is on a button and the user presses CNTRL-M the action related to the button press is executed in stead of the action related to the CNTRL-M keypress. This happens for instance in session "Shipment (fmlbd3100m100)". Initially the focus is on the button after the "Load Address" field. When now CNTRL-M is pressed, the session "Addresses (tccom4130s000)" is started. In stead the session: "Shipments (fmlbd3100m000)" should be started. Workaround Use menu entries or move focus to another control. Test Procedure See problem description. Affected Executables bw.exe Motive source TCS:800-151405 DevSchoenberg: # 28532 (BDNT20666): Bwprint: Improve registry access check Date: Mon, 21 Nov 2005 15:39:06 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Refer to BDNT20637 Workaround Refer to BDNT20637 Test Procedure Refer to BDNT20637 Affected Executables bwprint.exe DevSchoenberg: # 28525 (BDUX20670): default dbspace size changed Date: Mon, 21 Nov 2005 11:43:47 +0100 (CET) Created on: MaintMahler Type: bugfix Problem Description (Customer terms) default dbspace sizes are to small to complete full Gemini installation. Workaround enter 2000 for data and index dbspace during installation. Test Procedure install Gemini with default values Motive source TCS:800-137886 DevSchoenberg: # 28491 (BDUX20633): Uppercase users on Unix cannot login (merge from project BDUX20219) Date: Fri, 18 Nov 2005 09:54:02 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Because of a previous fix for Windows where users with one or more uppercase characters could not login, now user with uppercase character(s) on Unix are not able to login. Test Procedure Create a user with uppercase characters in its name on Windows and Unix. Try to login. Affected Executables bshell6.x ntbshell.exe Motive source DF:158525 DevSchoenberg: # 28480 (BDNT20632): Change bu4 + bs4 definitions Date: Thu, 17 Nov 2005 12:26:53 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Prepare for 64 bits data models Workaround NA Test Procedure Build with 32 and/or 64 bits data models Affected Executables In theory: many DevSchoenberg: # 28461 (BDUX20616): bdbvalidate dumps core Date: Wed, 16 Nov 2005 13:48:06 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) bdbvalidate crashes on tables having rare data types like DB.BITSET Test Procedure bdbvalidate6.2 -Ntdsmi000702 -pb50csp17 -C702 on system nlbauad1.ssainternal.net Affected Executables bdbvalidate DevSchoenberg: # 28412 (BDUX20575): Password aging on HP-UX Date: Mon, 14 Nov 2005 16:08:55 +0100 (CET) Created on: MaintMahler Type: bugfix Problem Description (Customer terms) HPUX Trusted Security is used. The password of the user is going to be expired. Therefore the following message is given by the operating system when trying to log in (e.g. using telnet): "your password will expire on .... (date)". But when logging into Baan using Worktop, the user is not notified about this and is not prompted to change the password. Workaround Do not use password expiration. Test Procedure It is required to have an HP-UX system, running in Trusted Security mode. Configure the following (you can do this via SAM): * Time Between Password Changes * Password Expiration Time * Password Expiration Warning Time * Password Life Time And have some accounts for which the following conditions are met: - an account which is expired: It should not be possible to log in Baan, and you cannot change the password. - an account which is in the warning period (going to be expired, but not yet) When logging into Baan, you will be asked if you want to change the password. When answering Yes you can change the password via the Terminal Emulator. - an account which is not expired and not in the warning period. You should be able to log in Baan without getting any messages. You can run also badmin6.2 -chkpwd to check and log in Baan and check. (Assuming that you have set up Password Expiratioin) Affected Executables badmin6.2 blogind6.2 Motive source DF:158752 DevSchoenberg: # 28385 (BDUX20570): Oracle installer crashes on large number of tablespaces Date: Fri, 11 Nov 2005 16:52:24 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Installation on Oracle failes when there are more than 10 regular tablespaces. Affected Executables ora8_adm DevSchoenberg: # 28381 (BDNT20560): Multiple selection of SLM servers changed to single selection Date: Fri, 11 Nov 2005 15:54:46 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Client configuration changed fro multiple to single selection listbox Workaround NA Test Procedure Client configuration from within SLM installer Affected Executables SLM installer DevSchoenberg: # 28375 (BDUX20480): function enum.descr() does not fallback to english language Date: Fri, 11 Nov 2005 14:03:03 +0100 (CET) Created on: MaintMahler Type: bugfix Problem Description (Customer terms) Error : ask_enum domain 'cisli.doct' is wrong (print.invoices.by.billing.request Workaround n/a Test Procedure Run following 3gl program to test. If no russian language is installed the function should return english now. function main() { string descr(25) domain tcyesno var var = tcyesno.no descr = enum.descr$("tcyesno", var, "R") } Affected Executables bshell6.2 Motive source DF:158992 DevSchoenberg: # 28365 (BDUX20537): QP: distributed query with not exists not working Date: Fri, 11 Nov 2005 10:49:43 +0100 (CET) Created on: DevSchoenberg Type: bugfix Problem Description (Customer terms) The following query gives an incorrect result if tables tdsls045 and tccom010 are handled by different database drivers: select orno,pono,srnb,cuno from tdsls045 where tdsls045.orno inrange 203000 and 709003 and not exists ( select * from tccom010 where tccom010.cuno=tdsls045.cuno and tccom010.comp=550 and _compnr = :1) order by tdsls045._index1 Effectively, the exists subquery will always return FALSE, meaning that the not exists subquery never filters out any row. Under the following condition the exists subquery is evaluated wrongly: 1. The subquery is handled by a different database driver than the main query; 2. The select in the subquery contains a "*" or the _compnr column; 3. The subquery contains a _compnr = ... expression. Workaround The simplest work-around is to replace the "*" in the subquery by any other field of the table (excluding the _compnr column), e.g: select orno,pono,srnb,cuno from tdsls045 where tdsls045.orno inrange 203000 and 709003 and not exists ( select cuno from tccom010 where tccom010.cuno=tdsls045.cuno and tccom010.comp=550 and _compnr = :1) order by tdsls045._index1 Test Procedure Set-up tabledef so that the tables are handled by different database drivers, e.g: tccom010:*:oracle8(ORACLE_HOME=/oracle/app/product/ora9.2,TWO_TASK=I3):N tdsls045:*:oracle8(ORACLE_HOME=/oracle/app/product/ora9.2,ORACLE_SID=B1):N Now run the query in the Problem Description (Customer terms) and observe that the proper rows are filtered out by the not exists expression. Affected Executables all database drivers Motive source DF:227642 DevSchoenberg: # 28359 (BDNT20555): Multple defined functions Date: Fri, 11 Nov 2005 09:43:00 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Build error Workaround NA Test Procedure Rebuild Affected Executables SLM Installer DevSchoenberg: # 28310 (BDNT20485): Crashing bwc.dll when using published environment from ADS Date: Wed, 9 Nov 2005 15:45:12 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Cannot use ERP environment information published in ADS : the BW / BECS software is crashing. STEPS TO BE FOLLOWED: 0 - Cannect using a domain user on "ELTONBV" Active Directory domain 1 - Open BECS. 2 - In "Options" menu, verify that Active Directory support is enabled. The Active Directory server can be left blank, or set to "DS1KA", this yield the same result. 3 - Open a BW connection to server MS1KA, or create a new one. 4 - Click on the "Published" button. 5 - You can choose two different env. : "baan" or "erpln61" Choose environment "baan". 6 - Click OK The BW configuration window and the SSA BECS window disappear. In the Application log, new event below is added : 21-7-2005 12:00:06 Application Error Error (100) 1000 N/A MS1KA Faulting application becs.exe, version 7.6.1.4, faulting module bwc.dll, version 7.6.1.4, fault address 0x00012fdb. Workaround No workaround. Test Procedure To test this you need to have: - 2 Baan environments (at least fat client's) installed on a Windows ADS (Active Directory Server) - the 2 Baan environments should be published into the ADS. (You can do this using the dssetup.exe utility) - in BECS (Tools->Options), enable Active Directory Open BECS Press New button, BW Configuration window is opened now Select Published Select one of the environments from the services drop down list Press OK Now the "Save As" dialog window should appear, and BECS/bwc.dll should not crash. Affected Executables bwc.dll Motive source DF:157969 DevSchoenberg: # 28281 (BDNT20498): DF159418 BW Login dialog hangup when changing Windows input language Date: Tue, 8 Nov 2005 15:10:40 +0100 (CET) Created on: MaintCorelli Type: bugfix Problem Description (Customer terms) The Windows input language can not be changed when password dialog appears in BW. This problem appears when BW is started from Worktop only. If BW is started from BECS no problem found. The problem is reproducable with latest BW for Corelli and onwards. Workaround Save password in .bwc file. Test Procedure See problem description. Affected Executables bw.exe Motive source DF:159418 DevSchoenberg: # 28256 (BDNT20463): General Table Maintenance in BIDI mode Date: Mon, 7 Nov 2005 11:20:07 +0100 (CET) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) In arabic language the layout of sessions: General Table Maintenance (ttaad4100) Display General Table Information (ttaad4500) look scattered. Test Procedure Run one of these sessions when table labels are translated to Arabic. Affected Executables bw.exe DevSchoenberg: # 28084 (BDNT20206): BW msi setup crash when having an inconsistent BW msi install Date: Tue, 25 Oct 2005 14:51:56 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When running setup.exe to install new BW version, the setup program generates an Access Violation when there is an inconsistent BW MSI install. The inconsistent BW MSI install does not contain the file bw.exe, and therefore it is consistent. (So according Windows this BW is correctly installed, but somehow the file bw.exe is missing). By running setup.exe of new BW I want to update this inconsistent BW installation so it becomes consistent again. Workaround Take care a bw.exe program is there. Test Procedure Have a BW MSI installed and remove the bw.exe. Now run setup.exe of a BW MSI install, in order to upgrade this BW MSI install. The setup should not crash or stop, but install the new BW version. Affected Executables setup.exe DevSchoenberg: # 27904 (BDNT19048): BaanIVc - number of copies in BwPrint not taken into account Date: Thu, 13 Oct 2005 15:54:27 +0200 (CEST) Created on: MaintBaanIVc Type: bugfix Problem Description (Customer terms) The number of copies defined in the driver properties are not considered by BWPRINT. In Portingset 6.1c0702 BW73 number of copies was automatically taken from the driver. But from portingset version 6.1c0704 till now this seems to be not taken into account anymore. Workaround Set the number of copies manually in the printer dialog. Test Procedure Set a default printer Define a default number of copies larger then 1 in the printer settings Run BwPrint Open a bpf file with a number of copies not set (default value is 1) Choose file->print, a print dialog opens. Check the number of copies, it shoul be the same as specified in the default printer settings Affected Executables bwprint.exe Motive source DF:157388 DevSchoenberg: # 27868 (BDNT20155): DF159713 Range selection in Grid not correct Date: Wed, 12 Oct 2005 14:51:59 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Testing agains Corelli backend with a BW for ERP LN (7.6a.01.2). When I select six lines from session tdsls4501m000 and choose Send To, only the last line arrives in the Excel spreadsheet. When I use a BW for Corelli (like 7.1d.06.158) the error does not occur. Test Procedure See problem description. Affected Executables bw.exe Motive source DF:159713 DevSchoenberg: # 27695 (BDUX20021): Error messages in ttaad4100 during data.input Date: Fri, 30 Sep 2005 10:33:58 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When editing a record in ttaad4100 a lot of messages appear on the BW Message string about a TssConvertTssToUtf8 failed (with 9b00) Test Procedure run ttaad4100 with a MB field that has a toupper domain constraint Affected Executables bshell6.2 Motive source DF:159359 DevSchoenberg: # 27648 (BDNT19979): TCS800-148369 BW Installer should not update full install Date: Wed, 28 Sep 2005 15:31:30 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) The installer recognizes an AS installation (Logic and BW) on the local machine and wants to overwrite it. It should skip the AS installation because this is an other product. Test Procedure See problem description Affected Executables setup.exe Motive source TCS:800-148369 DevSchoenberg: # 27610 (BDNT19955): DF159297 Planned delivery date/time not right Date: Tue, 27 Sep 2005 13:36:59 +0200 (CEST) Created on: MaintMahler Type: bugfix Problem Description (Customer terms) When entering a new order line the orderdate and ordertime from the order header will be copied automatically. E.g. 20-09-2005 13:00:00. When we change this orderdate now with the keyboard, the ordertime still keeps the same value (13:00:00). When we press TAB after changing the orderdate, we reach the ordertime field. Still the value is 13:00:00. However, when pressing TAB now, we leave the field and the value jumps to 00:00:00. This is not OK and will give problems. Test Procedure See problem description. Affected Executables bw.exe Motive source DF:159297 DevSchoenberg: # 27537 (BDNT19844): Port number for BaanLogon protocol increased Date: Fri, 23 Sep 2005 10:35:15 +0200 (CEST) Created on: MaintMahler Type: bugfix Problem Description (Customer terms) Port number for BaanLogon protocol is limited to 10000. Workaround n/a Test Procedure configure BaanLogon protocol for a number greater 10000 and save it. Affected Executables bw.exe DevSchoenberg: # 27471 (BDNT19644): Improve BW character window painting in BIDI mode Date: Tue, 20 Sep 2005 15:00:25 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Painting in Print to Display window in BIDI mode is not correct when another window is partly moved over the BW display window. Test Procedure See problem descripion. Affected Executables bw.exe DevSchoenberg: # 27351 (BDNT19739): DF158932 Do not sent TAB codes to Bshell in an Edit field Date: Thu, 15 Sep 2005 09:40:20 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When copy/pasting text from an Excell Worksheet, and the cell format is a merged cell, TAB characters are appended to the end of the inserted data. Test Procedure See problem description. Affected Executables bw.exe Motive source DF:158932 DevSchoenberg: # 27203 (BDNT19601): BIDI determine BIDI mode in BW from backend user language Date: Tue, 6 Sep 2005 14:50:47 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) BW should by default switch to BIDI mode when the backend user language is a BIDI language (Hebrew or Arabic). In addition BW can be forced to use BIDI mode when the "right to left" flag is set in the .bwc file. Test Procedure Set backend language to Arabic or Hebrew and check if BW runs in BIDI mode. Affected Executables bw.exe DevSchoenberg: # 27017 (BDNT19466): BW crashes when locale set to ISO88596 Date: Fri, 26 Aug 2005 12:03:35 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When the backend locale is set to ISO88596 (Arabic) BW crashes with a general protection fault. Test Procedure See problem description. Affected Executables bw.exe DevSchoenberg: # 26942 (BDNT19392): DF157441 Cannot re-edit Japanese text with Word without RTF Date: Tue, 23 Aug 2005 11:00:34 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When I try to re-edit Japanese text with the External Editor "Word without RTF", the Japanese characters are corrupted in MS-Word. Test Procedure Use tttxt1100m000 and a text group using the editor: Word without RTF. Affected Executables bw.exe Motive source DF:157441 DevSchoenberg: # 26925 (BDNT19378): Manual Merge of BDNT19352 Date: Mon, 22 Aug 2005 09:38:43 +0200 (CEST) Created on: MaintMahler Type: bugfix Problem Description (Customer terms) 1) On the servers where DM jobrunner is running, there are a lot of entries in the HKEY_CLASSES_ROOT registry. The entries have the name: Baan.Application.radxxxxxtmp, where xxxxx is a hexadecimal sequence number. At the moment: -To open this part of the registry takes a long time -The backup of the system state FAILS !! 2) In addition another problem was detected that the automation entrie of BaanIV .bwc files was modified by a Gemini version of the bwc.dll. Test Procedure See problem description. Affected Executables bwc.dll Motive source DF:158449 DevSchoenberg: # 26895 (BDNT19357): Manual merge of BDNT19344 Date: Thu, 18 Aug 2005 16:38:53 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When upgrading Baan Windows from an InstallShield 3 version of BW, Un-installing the InstallShield 3 version sometimes takes a long time. During this un-install action, nothing seems to happen and no window is visible. Test Procedure See problem description. Affected Executables setup.exe Motive source TCS:800-148085 DevSchoenberg: # 26627 (BDNT19106): Show new version in BW setup update dialog Date: Thu, 28 Jul 2005 12:26:48 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) New Baan Windows version not visible when existing version is updated. Test Procedure Update installed Baan Windows version using MSI setup. Affected Executables setup.exe DevSchoenberg: # 26608 (BDNT19056): Unicode: Underlines in ttaad4100 Date: Wed, 27 Jul 2005 09:15:42 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) In the session ttaad4100, strange underlines are sometimers displayed in the value fields for the primary keys. This only occurs in case the backend language is set to a multibyte language (e.g. japanese). The problem becomes visible when switching between forms in ttaad4100 (e.g using the right and left arrow keys). Test Procedure See problem description. Affected Executables bw.exe DevSchoenberg: # 26602 (BDNT19065): Implement BIDI enhancements for BWPRINT Date: Tue, 26 Jul 2005 12:05:34 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) For BIDI support in ERP LN, some small enhancements in BWPRINT are needed. These enhancements are implemented through this project. Test Procedure Print report in Hebrew or Arabic language through BWPRINT. Affected Executables bwprint.exe DevSchoenberg: # 26514 (BDNT19003): Unicode: Create.local.directory fails with wrong error code Date: Mon, 18 Jul 2005 07:55:44 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) The function create.local.directory("${BSE_TMP}") doesn't work any more in the Unicode bw 7.6b.6. The return value is -123. Windows error -123 means "The filename, directory name or volume label syntax is incorrect". The creation of the directory "${BSE}/tmp" works correct. If this directory doesn't exist the directory is created and return value 0 is given, if the directory already exist the return value -183 is given. Windows error -183 means "Cannot create a file when that file already exists. In the none Unicode bw it still works correct. Test Procedure See problem description. session: tewhrodm can be used to reproduce. Affected Executables bw.exe Motive source TCS:800-147593 DevSchoenberg: # 26487 (BDNT18985): Tabbing trough checkbox leaves a dotted line around the label Date: Fri, 15 Jul 2005 10:08:47 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When tabbing through check boxes, dots are left at field labels where control has been. Normally the dots move with a move of control. Test Procedure See above. Affected Executables bw.exe Motive source TCS:800-147532 DevSchoenberg: # 26425 (BDNT18938): BW crash when clicking a row in grid Date: Mon, 11 Jul 2005 16:17:07 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) When in session tfgld4573m000 I double click on a record, I get a fatal error and I am disconected from the server. Test Procedure See problem description Affected Executables bw.exe Motive source TCS:800-147456 DevSchoenberg: # 26370 (BDNT18899): BwPrint: line drawing on fax Date: Wed, 6 Jul 2005 17:14:47 +0200 (CEST) Created on: MaintBaanIVc Type: bugfix Problem Description (Customer terms) BwPrint prints vertical lines incorrect to LanFax printer Affected Executables bwprint.exe Motive source DF:156605 DevSchoenberg: # 26211 (BDNT18771): Unicode: Input in edit grid behaves strange Date: Wed, 29 Jun 2005 14:51:36 +0200 (CEST) Created on: MaintDvorak Type: bugfix Problem Description (Customer terms) Strange things happen in inputting in Grid Windows. There are several patterns for strange things. Good example session is tcmcs0139m000 (Signal). When I enter new code and Japanese description by entering Tab. and soon after entering Japanese description, push the "Save" icon causes the corrupted description at the record. Especially, when previous description is longer than current one, part of previous descriptions appears after current description after saving (or after re-open). It looks that some hidden (save?) buffer is not cleared. Test Procedure See problem description. Affected Executables bw.exe