Bugfixes BI version 7.1b.01.133 Corelli: # 9100 (VHNT3600): Desktop browser and BI Date: Fri, 9 Jun 2000 10:31:37 +0200 (METDST) Release: Corelli Date: 2000/06/09 Script: MergeProject Project: VHNT3600 Created on: Grieg Type: bugfix Problem: Problem Description (Customer terms) I) If the user has set his startup program to desktop in the user data, the desktop is displayed with a wrong geometry. The shown window is to big, the right half of it consists only of background. All descriptions of the Icons are missing. II)When printing to display from any session in Baan when logged on via the BI Baan Internet server, the report display screen has the following problems. 1) No Menu bar is displayed. 2) No Tool bar is displayed. 3) The scroll bars dont work. (Both Horizontal and vertical) Problem Description (Technical terms) Several BI problems in Character Window and GWindow. Workaround None Test Procedure - Test desktop browser with BI. - Test report writing to Display Browser with BI. (Note: also an update of ostpsplopen at the BaanERP server is needed for this). Affected Executables bisetup.class Scopus defectnumber(s) Scopus casenumber(s) Priority (e.g. 10) 86664 30 93952 20 Comments Corelli: # 9854 (VHNT4370): BI Character window bug Date: Fri, 15 Sep 2000 15:51:03 +0200 (METDST) Release: Corelli Date: 2000/09/15 Script: MergeProject Project: VHNT4370 Created on: Verdi Type: bugfix Problem: Problem Description (Customer terms) ttaad4100 can run but cannot define key to search when used via BI Server. Problem Description (Technical terms) Attribute DsNwindow was not implemented for a character window in BI. Workaround none Test Procedure The problem with changing the search key (sort order) in ttaad4100 can be reproduced by me. 1) Start ttaad4100 2) When started: select for example table tt aad 200, company 000 and give "Y" on Choice field. 3) The table is opened now, and first record is displayed 4) Give "k" on Choice field 5) Now the following appears: 1 User 2 Company and User 3 Package and User 4 Language and User 5 Language, User and Package 6) Give "2" on Choice field, the second index will be selected now. Press Enter to confirm. Now, normaly the "window" showing the 1 till 5 sort orders, disappears, and the second index is activated now. When pressing "n" (this is Next record), the next record will be shown according the second index. In the BI interface the "window" showing the 1 till 5 sort orders does not appear. When doing one time "n" nothing happens. It's like the window of ttaad4100 is frozen. Affected Executables bisetup.class Scopus defectnumber(s) Scopus casenumber(s) Priority (e.g. 10) 99481 843002 30 Comments Corelli: # 9863 (VHNT4373): BI problems Date: Mon, 18 Sep 2000 09:37:46 +0200 (METDST) Release: Corelli Date: 2000/09/18 Script: MergeProject Project: VHNT4373 Created on: Corelli Type: bugfix Problem: Problem Description (Customer terms) Labels not shown in Run program Dialog for BI. Problem Description (Technical terms) DsNwordWrap attribute not implemented in BI for the label object while the run program dialog uses this. Workaround None Test Procedure Start BI and start the run program dialog. Affected Executables bisetup.class Scopus defectnumber(s) Scopus casenumber(s) Priority (e.g. 10) xxxxx yyyyy zz Comments Corelli: # 10163 (VHNT4559): Grid problem in BI Date: Tue, 10 Oct 2000 17:23:59 +0200 (METDST) Release: Corelli Date: 2000/10/10 Script: MergeProject Project: VHNT4559 Created on: Verdi Type: bugfix Problem: Problem Description (Customer terms) When accessing BaanERP via BI interface, in the session tcibd0501m000, width of "project segment" can not be adjusted. There is no problem to change the width under BW interface. Problem Description (Technical terms) This was mapped in BI to Covered cells. Covered cells did not work correctly in the Objective Grid code. Therefore it has been changed to Floating cells, which have the same behavior as in BW. Workaround None Test Procedure See problem description Affected Executables bisetup.class Scopus defectnumber(s) Scopus casenumber(s) Priority (e.g. 10) 103179 552621 20 21242 513002 30 Comments